Data Bus Cable Electrical & Physical Characteristics

Cable part # Impedance Ohms Capacitance pF/foot Number of Conductors Gauge AWG Outer Dia. Inches Weight lbs/100 ft. Bend Radius Temp. Range (Celsius) Total Shields Applications
442202 62 27.8 2 22 0.150 1.74 0.075 -55˚ to +150˚ C 1 ARINC 429
422202 70 25.0 2 22 0.170 1.35 0.850 -55˚ to +200˚ C 1 ARINC 429
422402 70 24.5 2 24 0.150 1.35 0.750 -55˚ to +200˚ C 1 ARINC 429
522402 70 21.0 2 24 0.125 1.25 0.625 -55˚ to +200˚ C 1 ARINC 429
312402 78 19.2 2 22 0.274 2.50 1.400 -55˚ to +150˚ C 3 ARINC 453, ARINC 708 Weather Radar, General Purpose
432202 78 18.7 2 22 0.170 2.14 0.850 -55˚ to +200˚ C 1 Mil-Std. 1553
4122021 78 25.0 2 22 0.176 2.00 1.000 -55˚ to +200˚ C 2 Mil-Std. 1553
912204 90 20.0 4 22 0.192 2.90 1.000 -55˚ to +150˚ C 2 USB
912404 90 20.0 4 24 0.180 2.30 0.900 -55˚ to +150˚ C 2 USB
392402 100 12.4 2 24 0.162 2.00 0.800 -55˚ to +200˚ C 2 10 Base T, LAN
392404 100 12.4 4 24 0.234 3.00 1.200 -55˚ to +200˚ C 2 ARINC 646, LAN, 10 Base T CAT 5
382410A 100 12.8 10 24 0.395 9.00 2.400 -55˚ to +85˚ C 2 LVDS Video Cable for LCD Displays and DVI Applications
922404 100 15.0 4 24 0.240 3.75 1.500 -55˚ to +200˚ C 3 ARINC 664, Cat 5e, LAN, 10/100 Base T
922408 100 15.0 8 24 0.299 6.00 1.500 -55˚ to +200˚ C 3 Cat 5e, LAN
422404 100 13.5 4 24 0.165 2.30 1.000 -55˚ to +150˚ C 1 LAN,
10/100 Base T
522404 100 15.0 4 24 0.240 4.40 1.200 -55˚ to +150˚ C 2 Cat 5e
922604 100 15.0 4 26 0.195 2.40 1.100 -55˚ to +150˚ C 2 Cat 5e
922608 100 15.0 8 26 0.230 3.40 1.400 -55˚ to +150˚ C 2 Cat 5e
922204 100 15.0 4 22 0.250 3.90 1.600 -55˚ to +150˚ C 2 Cat 5e
962408 100 13.0 8 24 0.250 4.30 1.900 -55˚ to +150˚ C 2 100/1000 Base T
912406 110 12.0 4 24 signal 0.338 6.10 1.700 -55˚ to +150˚ C 2 IEEE 1394 Firewire
2 22 power
922406 110 12.0 4 24 signal 0.345 8.60 1.720 -55˚ to +150˚ C 2 IEEE 1394 Firewire extended range
2 18 power
322402 125 12.0 2 24 0.204 2.50 1.020 -55˚ to +200˚ C 2 ASCB-D, C data Bus for EPIC AV-900, Sperry SPZ-8000, Cept-E1
502402 125 12.0 2 24 0.204 2.50 1.020 -55˚ to +200˚ C 2 ASCB-D or C data bus for EPIC AV-900, Cept-E1
622202 125 12.0 2 22 0.288 5.00 1.450 -55˚ to +150˚ C 2 Cept E1