An image showing the various sizes and colors of Zyrad wiring.

Key Features

  • Operating temperature - 65°C to + 155°C
  • 600 V to 1000 V Rating
  • Tin Plated Conductors
  • Range of 11 standard colors and striped color options for ease of identification
  • Flame Retardant 
  • Low Smoke Halogen Free versions available

Click here to download the Raydex Wire & Cable Capabilities

Zyrad™ 500

Designed, manufactured and fully released to meet the requirements of the UL AWM Styles 3288, 3289, and CSA CL 1503 Specifications.

Nominal Conductor OD

Nominal Insulation (mm)

Nominal Overall Diameter (mm)

AWG

mm

mm²

Conductor (stranding)

UL AWM 3288 / 3289 • Tin Plated Conductors • 600V • 150°C *

24

0.60

0.22

 07/0.200

0.80

2.20

24

0.65

0.25

 19/0.130

0.80

2.25

22

0.75

0.34

 19/0.150

0.80

2.36

22

0.93

0.50

 16/0.200

0.80

2.53

20

1.14

0.75

 24/0.200 

0.80

2.74

18

1.32

1.00

 32/0.200

0.80

2.92

16

1.60

1.50

 30/0.250

0.80

3.20

14

2.07

2.50

 50/0.250

0.80

3.67

12

2.60

4.00

 56/0.300

0.80

4.20

10

3.19

6.00

 84/0.300 

0.80

4.79

8

4.20

10.00

 80/0.400 

1.20

6.60

6

5.70

16.00

 126/0.400

1.60

8.90

4

7.10

25.00

 196/0.400

1.60

10.30

2

8.50

35.00

 278/0.400

1.60

11.70

1/0

10.30

50.00

 399/0.400

2.00

14.30

2/0

12.40

70.00

 361/0.500

2.00

16.40

3/0

14.50

95.00

 475/0.500

2.00

18.50

4/0

16.00

120.00

 608/0.500

2.00

20.00

* Will withstand varnish bake temperatures of +190°C and short term exposure at + 250°C

Zyrad™ 555

Meets Thermal/Insulation Class "F" for use in generators, electric motors, and transformers.

Nominal Conductor OD

Nominal Insulation (mm)

Nominal Overall Diameter (mm)

AWG

mm

mm²

Conductor (stranding)

Tin Plated Conductors • 600V • 155°C * • Class “F”

24

0.65

0.25

19/0.130

0.40

1.45

22

0.90

0.50

19/0.180

0.43

1.75

20

1.14

0.75

24/0.200

0.55

2.24

18

1.32

1.00

32/0.200

0.60

2.52

16

1.60

1.50

30/0.250

0.60

2.80

14

2.07

2.50

50/0.250

0.60

3.20

12

2.60

4.00

56/0.300

0.65

3.90

10

3.19

6.00

84/0.300

0.70

4.59

8

4.20

10.00

80/0.400

1.00

6.20

6

5.70

16.00

126/0.400

1.10

7.90

4

7.10

25.00

196/0.400

1.20

9.50

2

8.50

35.00

278/0.400

1.30

11.10

1

10.30

50.00

399/0.400

1.50

13.30

0

12.40

70.00

361/0.500

1.60

15.60

3/0

14.50

95.00

475/0.500

1.80

18.10

4/0

16.00

120.00

608/0.500

1.80

19.60

* Will withstand varnish bake temperatures of + 190°C and short term exposure at + 250°C

Zyrad™ 400

Designed, manufactured and fully released to meet the requirements of the UL AWM Style 3266 and CSA CL 1252 Specifications.

Nominal Conductor OD

Nominal Insulation (mm)

Nominal Overall Diameter (mm)

AWG

mm

mm²

Conductor (stranding)

Tin Plated Conductors • 300V • 125°C • Thin Wall Insulation

24

0.60

0.21

19/0.120

0.40

1.40*

24

0.64

0.24

19/0.127

0.40

1.44*

22

0.75

0.33

19/0.150

0.40

1.55*

20

1.00

0.60

19/0.200

0.40

1.80*

18

1.25

0.93

19/0.250

0.40

2.05*

16

1.50

1.34

19/0.300

0.40

2.30*

14

1.75

1.82

37/0.250

0.40

2.55*

12

2.24

2.97

37/0.320

0.40

3.04*

10

2.80

4.65

37/0.400

0.40

3.60*

* These sizes are not included in CSA CL 1252

Zyrad™ 700

Halogen free with low toxicity and low smoke emissions for assured safety and security

Nominal Conductor OD

600V

700V

AWG

mm

mm²

Conductor (stranding)

Nom. Insulation (mm)

Nom. Overall Diameter (mm)

Nom. Insulation (mm)

Nom. Overall Diameter (mm)

Halogen Free • Tin Plated Conductors • 150°C

 

24

0.62

0.25

19/0.130

0.40

1.42

0.80

2.22

22

0.87

0.50

16/0.200

0.43

1.73

0.80

2.47

20

1.08

0.75

24/0.200

0.55

2.18

0.80

2.68

18

1.22

1.00

32/0.200

0.60

2.42

0.80

2.82

16

1.50

1.50

30/0.250

0.60

2.70

0.80

3.10

14

1.94

2.50

50/0.250

0.60

3.14

0.80

3.54

12

2.46

4.00

56/0.300

0.65

3.76

0.80

4.06

10

2.92

6.00

84/0.300

0.70

4.32

0.80

4.52

8

3.95

10.00

80/0.400

1.00

5.95

1.20

6.35

6

5.70

16.00

126/0.400

1.10

7.90

1.60

8.90

4

7.20

25.00

196/0.400

1.20

9.60

1.60

10.40

2

8.50

35.00

278/0.400

1.30

11.10

1.60

11.70

1

10.30

50.00

399/0.400

1.50

13.30

2.00

14.30

0

12.50

70.00

361/0.500

1.60

15.70

2.00

16.50

3/0

14.30

95.00

475/0.500

1.80

17.90

2.00

18.30

4/0

16.00

120.00

608/0.500

1.80

19.60

2.00

20.00

Trakrad™

Nominal Conductor OD

Nominal Insulation (mm)

Nominal Overall Diameter (mm)

AWG

mm

mm²

Conductor (stranding)

Tin Plated Conductors • 1900 / 3300V  Grey  90°C * (TDE 76/P/16)

22

0.87

0.50

16/0.200

0.8

2.59

20

1.08

0.75

24/0.200

0.8

2.82

18

1.22

1.00

32/0.200

0.8

2.92

16

1.40

1.16

37/0.200

0.8

3.00

14

1.50

1.50

30/0.250

0.8

3.32

12

1.75

1.80

37/0.250

0.8

3.50

10

1.94

2.50

50/0.250

0.8

3.76

8

2.10

2.60

37/0.300

0.8

3.90

6

2.47

4.00

56/0.300

0.8

4.29

4

2.80

4.70

37/0.400

1.00

4.80

2

2.93

6.00

84/0.300

1.20

5.67

1

3.60

7.70

61/0.400

1.20

6.00

0

4.60

10.00

80/0.400

1.20

7.00

3/0

5.70

16.00

126/0.400

1.20

8.10

4/0

7.10

25.00

196/0.400

1.60

10.3

2

8.50

35.00

276/0.400

1.60

11.7

1/0

10.30

50.00

396/0.400

1.70

13.7

2/0

12.40

70.00

360/0.500

1.80

16.0

3/0

14.50

95.00

475/0.500

2.00

18.5

4/0

16.00

120.00

608/0.500

2.20

20.4

300,000cmil

18.00

150.00

756/0.500

2.30

22.6

350,000cmil

20.00

185.00

925/0.500

2.40

24.8

450,000cmil

23.00

240.00

1221/0.500

2.40

27.8

600,000cmil

26.00

300.00

1525/0.500

3.00

32.0

800,000cmil

30.00

400.00

2013/0.500

3.00

36.0

* Insulation rated to + 250°C