ARINC 600 Quick Reference Guide-Cooled

MCU
(LRU Width)
A
Tray Width
B Side Fan
Tray Width
Tray Length Front Hold Down Mounting Holes Tray Bottom Fan Location Spec Number
2 MCU 2.51 [63.8] - - - - 14.92 [379.0] Insertion /
Extraction Hold Downs
None Deformation with Metering Plate Bottom 6-00S1N1C1
2 MCU 2.51 [63.8] 5.08 [129.0] 14.92 [379.0] None Left Side 6-02S1N1C2
2 MCU 2.51 [63.8] 5.08 [129.0] 14.92 [379.0] None Right Side 6-02S1N1C3
2 MCU 2.51 [63.8] - - - - 20.06 [509.5] None Bottom 6-02L1N1C1
2 MCU 2.51 [63.8] - - - - 20.06 [509.5] None Rear 6-02L1N1C4
3 MCU 3.81 [96.8] - - - - 14.92 [379.0] None Bottom 6-03S1N1C1
3 MCU 3.81 [96.8] 6.38 [162.1] 14.92 [379.0] None Left Side 6-03S1N1C2
3 MCU 3.81 [96.8] 6.38 [162.1] 14.92 [379.0] None Right Side 6-03S1N1C3
3 MCU 3.81 [96.8] - - - - 20.06 [509.5] None Bottom 6-03L1N1C1
3 MCU 3.81 [96.8] - - - - 20.06 [509.5] None Rear 6-03L1N1C4
4 MCU 5.13 [130.3] - - - - 14.92 [379.0] None Bottom 6-04S1N1C1
4 MCU 5.13 [130.3] 7.7 [195.6] 14.92 [379.0] None Left Side 6-04S1N1C2
4 MCU 5.13 [130.3] 7.7 [195.6] 14.92 [379.0] None Right Side 6-04S1N1C3
4 MCU 5.13 [130.3] - - - - 20.06 [509.5] None Bottom 6-04L1N1C1
4 MCU 5.13 [130.3] - - - - 20.06 [509.5] None Rear 6-04L1N1C4
6 MCU 7.73 [196.3] - - - - 14.92 [379.0] None Bottom 6-06S1N1C1
6 MCU 7.73 [196.3] 10.3 [261.6] 14.92 [379.0] None Left Side 6-06S1N1C2
6 MCU 7.73 [196.3] 10.3 [261.6] 14.92 [379.0] None Right Side 6-06S1N1C3
6 MCU 7.73 [196.3] - - - - 20.06 [509.5] None Bottom 6-06L1N1C1
6 MCU 7.73 [196.3] - - - - 20.06 [509.5] None Rear 6-06L1N1C4
8 MCU 10.33 [262.4] - - - - 14.92 [379.0] None Bottom 6-08S1N1C1
8 MCU 10.33 [262.4] 12.9 [327.7] 14.92 [379.0] None Left Side 6-08S1N1C2
8 MCU 10.33 [262.4] 12.9 [327.7] 14.92 [379.0] None Right Side 6-08S1N1C3
8 MCU 10.33 [262.4] - - - - 20.06 [509.5] None Bottom 6-08L1N1C1
8 MCU 10.33 [262.4] - - - - 20.06 [509.5] None Rear 6-08L1N1C4

Dimensions are in inches, bracketed [numbers] represent millimeters.

115VAC 400 Hz Fans (28VDC are also available)

ECS Fan Cooled Trays conform to ARINC Level I maximum cooling requirements. (see Glossary of Terms for definition)

To determine cooling requirements, check the avionics equipment installation manual or call ECS Customer Service

Note: Standard off-the-shelf trays can be modified to meet custom requirements. Refer to the ARINC 600 Custom Tray Worksheet.